As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
0.300' CRACK EXTENDING FWD OF FASTENER ON R1 BEAR STRAP INTERIOR SIDE . REMOVED RAIN GUTTERS (2EA) FROM REPAIR AREA IAW SRM 51-40-02-0G-0. FABRICATED TAPERED SHIM IAW EA 21-153-03542 STEP 10 FIG.1. COMPLETED FABRICATION OF REPAIR IAW EA 21-153-03542 STEP 10 FIG.1. APPLIED TOP COAT AT EXTERNAL FUSELAGE IAW AMM 51-21-73-370-803. REPAIRED IAW SRM 53-10-01-2R-6 AND EA M-21-153-03542.