What was found
CORROSION ON R2 DOOR SILL, BS 947.5-992.8. REMOVED CORROSION IAW SRM 51-10-02-0G-0. PERFORMED UT THICKNESS INSP ON REWORKED AREA IAW NDT PART 4 51-00-00, PROC 3. EVALUATED REWORKED AREA AND FOUND OUT OF LIMITS IAW SRM 53-70-15-1A-1. REMOVED THE DOOR SILL IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED IAW SRM 51-40-05 AND DWG 147A8501. INSTALLED IAW SRM 51-40-02-0G-0, AND DWG 147A8501.