What was found
CORROSION AFT CABIN WET AREA FLOOR SUPPORT WEB FROM BL-0 TO LBL17 STA 1016. EVALUATED CORRODED AREA, FOUND EXFOLIATING CORROSION OUT OF LIMITS IAW SRM 51-10-02-0G-0. REMOVED DAMAGE WEB IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED THE NEW WEB IAW SRM 51-40-05-0G-0. WEB INSTALLED IAW SRM 51-40-02-0G-00, AND DWG 147A5600.