What was found
CORROSION FOUND FWD CARGO DOOR CUT-OUT FWD SHIELD, SPOTS OF CORROSION AROUND FASTENER HOLES. REMOVED CORROSION IAW SRM 51-10-02-0G. PERFORMED UT THICKNESS ON REWORKED AREA IAW NDTM, PART 4, 51-00-00, PROCEDURE 3. MINIMUM FOUND: 0.019'. AFTER REMOVAL OF CORROSION FOUND OUT LIMITS IAW AMM 53-00-53-1A. REMOVED FWD CARGO FWD SHIELD IAW SRM 51-40-02-0G-0. LOCATED AND DRILLED HOLES ON NEW SHIELD IAW SRM 51-10-A02-0G-0. TREATED AND PRIMED IAW SRM 51-20-01-0G-0, AND AMM 51-21-72-370-804. APPLIED TOP COAT IAW AMM 51-21-73-370-804. INSTALLED SHIELD IAW SRM 51-40-02-0G-0, AND DWG 143A8126.