What was found
TE FLAPS LOCKED OUT AT 10 UNITS; FSEU SHOWS FAULT CODE 27-53258. / [01] BITE OF FSEU SHOWING LATCHED FAULT 27-53250. TS PER FIM 27-59 TASK 801. REPLACED #1 SKEW SENSOR IAW AMM 27-59-01. OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TE FLAPS LOCKED OUT AT 10 UNITS; FSEU SHOWS FAULT CODE 27-53258. / [01] BITE OF FSEU SHOWING LATCHED FAULT 27-53250. TS PER FIM 27-59 TASK 801. REPLACED #1 SKEW SENSOR IAW AMM 27-59-01. OPS CHECK GOOD.