What was found
CORROSION FLOOR STRUCTURE INNER CHORD LOCATED BETWEEN BS967 TO BS986.5 LBL51 WL208.1. REPLACED FLOOR SUPPORT IAW SRM 51-40-02 AND DWG 147A8501 SHEET 91 REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.