What was found
CORROSION ON WEB LOCATED FLOOR STRUCTURE BTW BS 1016 TO 1040 BL 5 AT AFT GALLEY AREA. REPLACED THE WEB IAW SRM 51-10-02, PARAGRAPH 9, SRM 51-40-02, AND DRAWING 147A5700, SHEET 99, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON WEB LOCATED FLOOR STRUCTURE BTW BS 1016 TO 1040 BL 5 AT AFT GALLEY AREA. REPLACED THE WEB IAW SRM 51-10-02, PARAGRAPH 9, SRM 51-40-02, AND DRAWING 147A5700, SHEET 99, REV B.