What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT LBL 24, BS 400+14, 420+14, 440+2, 440+18, 460+10, 460+14, 480+6, 480+10, 480+14. REMOVED CORROSION IAW SRM 51-10-02 FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2 ALLOWABLE DAMAGE PARA G 4A (2), FIGURE 103, DETAIL D. FABRICATED, LOCATED, AND DRILLED A NEW FLOOR TO SIDEWALL SUPPORT AND SPLICE IAW SRM 51-40-05-0G-0, SRM 53-00-53-2R-5, AND DWG 143A7501. TREATED AND PRIMED.