What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24, BS 500A+6, 500A+14, 500B+14, 500C+2, 500C+6, 500C+10, 500C+14. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, PARA 4A (2), FIG 103, DETAIL D. FABRICATED, LOCATED, AND DRILLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0 AND DWG 143A7501. APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW SRM 51-20-01 AND SOPM 20-41-02. WORK COMPLETE.