What was found
CORROSION ON FWD CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 24 BS 400+2 & 400+14. REMOVED CORROSION IAW SRM 51-10-02. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2, PARA 4A (2), FIG 103, DETAIL D. FABRICATED, LOCATED, AND DRILLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0, AND DWG 143A7501. APPLIED CHEMICAL CONVERSION COATING AND PRIMED IAW SRM 51-20-01 AND SOPM 20-41-02. WORK COMPLETE.