What was found
CORROSION ON AFT CARGO BAY RT FLOOR TO SIDEWALL SUPPORT BS 727+4 - 767, RBL 20 - 22, WL 156. REMOVED CORROSION AND FOUND TO BE OUT LIMITS IAW SRM 53-00-53-1A-2, PARAG.4 (2), DETAIL D, FIG 103 AND SRM 53-60-53-0I-2 IDENT 2. FABRICATED A NEW SUPPORT IAW SRM 51-40-05, DWGS 146A7502 & 146A7500 AND INSTALLED.