What was found
CRACKED ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 UPPER SURFACE WL 208.1. REPLACED THE ANGLE FLOOR STRUCTURE IAW SRM 51-40-02, AND DWG 273A9110, SHEET 5, REV A.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACKED ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 UPPER SURFACE WL 208.1. REPLACED THE ANGLE FLOOR STRUCTURE IAW SRM 51-40-02, AND DWG 273A9110, SHEET 5, REV A.