What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 LBL 46 AT FWD GALLEY. REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE IAW SRM 51-40-02, AND DWG 141A5400, REV -.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN BS 312 TO BS 328 LBL 46 AT FWD GALLEY. REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE IAW SRM 51-40-02, AND DWG 141A5400, REV -.