What was found
CORROSION ON FWD CARGO BAY LT FLOOR TO SIDEWALL SUPPORT, BS 420+13 - 500C +17, RBL 24, WL 156. BLENDED CORROSION AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. FABRICATED, LOCATED, AND DRILLED A NEW SIDEWALL SUPPORT AND SPLICE,BS 396 - 500D IAW SRM 51-40-05-0G-0, AND DWG 143A7501; ID:0112, REV A, AND SRM 53-00-53-2R-6. APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802. APPLIED PRIMER IAW AMM 51-21-72-370-804, INSTALLED THE SPLICE IAW SRM 53-00-53-2R-6, AND INSTALLED ADHESIVELY BONDED NUTPLATES IAW SRM 51-40-10-2R-0. INSTALLED A NEW FLOOR TO SIDEWALL SUPPORT IAW SRM CH 51-40-02 AND DRAWING 143A7500.