What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT, LBL 21, BS 787+5, 787+14, AND BS 807+8. FOUND TO BE OUT OF LIMIT IAW SRM 53-00-53-1A-2. FABRICATED, LOCATED, AND DRILLED A NEWFLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-05-0G-0, SRM 53-00-53-2R-6, AND DWG 146A7502, REV. APPLIED CHEMICAL CONVERSION COATING AND PRIMER IAW AMM SRM 51-20-01, AND SOPM 20-41-02. INSTALLED SPLICE REPAIR ON FLOOR TO SIDEWALL SUPPORT AND INSTALLED NUTPLATES IAW SRM 53-00-53-2R-6, SRM 51-40-10-2R-0, AND DWG 146A7502 REV-.