What was found
CORROSION ON AFT CARGO BAY FRAME AT BS 947 RBL 20; RBL 18. REMOVED CORROSION ON FRAME AT INNER CHORD. FOUND OUT ALLOWABLE DAMAGE LIMITS IAW SRM 53-00-07-1A-1 ALLOWABLE DAMAGE 2 FIGURE 102 DETAIL C. REMOVED FRAME AT BS 947 RBL 20; RBL 18. IAW SRM 51-40-02 AND 51-40-05. LOCATED AND DRILLED A NEW FRAME IAW DWG 147A1047 REV D, AND SRM 51-40-02 ;51-40-05. INSTALLED NEW FRAME IAW DWG 147A1047, REV -, AND SRM 51-40-02, 51-40-05.