What was found
FLAP TRACK FAIRING 542BB HAS A CRACK ON THE INNER SKIN 47 INCHES AFT OF THE LEADING EDGE, DAMAGE IS OUT OF ALLOWABLE LIMITS IAW SRM 57-53-70-1A-1, FIGURE 101, AND 104, ZONE 1, PARA 4A. TAP TESTED, DEBOND NOTED. REMOVED 1 INCH DIA OF INNER SKIN AND PARTIAL DEPTH CORE IAW SRM 51-70-04-2R-2 PARA 4.A-B. UT INSPECTED DAMAGE REMOVAL IAW NDTM PART 4, 51-00-02. NO DEBONDS NOTED. REPAIRED IAW EA 22-157-03470.