What was found
CORROSION FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT PLATE, HAD MULTIPLE AREAS AROUND NUTPLATE HOLES BS 500C TO 500I, RBL24.5, WL156 FABRICATED A NEW FLOOR TO SIDEWALL SUPPORT PLATE AND REPAIR PARTS IAW SRM 53-00-53-2R-5, STEPS 4 D - I, AND EA M-22-153-01550. PRIMED AND INSTALLED NUTPLATES IAW SRM 53-00-53-2R-5, STEPS 4, J & K, DWG 143A7500, AND EA M-22-153-01550. DAMAGE WAS REPAIRED IAW SRM 53-00-53-2R-5, REPAIR 5, EA-M-22-153-01550, AND DWG 143A7500.