What was found
MAIN CABIN FWD WET AREA BETWEEN STATION 380-400 BL-0 UPPER CORD ANGLE CRACKED AT FASTENER HOLE<[01] REMOVED MAIN CABIN UPPER CHORD ANGLE BETWEEN STA 380-400 BL-0 PER B737-700 SRM 51-40-02-0G-0;[02] LOCATED AND DRILLED MAIN CABIN UPPER CHORD ANGLE BETWEEN STA 380-400 BL-0 PER B737-700 SRM 51-10-02-0G-0;[03] VERIFIED STEPS 1 AND 2;[04] OK TO INSTALL ANGLE;[05] INSTALLED MAIN CABIN FWD WET AREA BETWEEN STA 380-400 BL-0 UPPER CORD ANGLE PER B737-700 SRM 51-40-02-0G-0.