What was found
RH I/B FLAP T/E WEDGE DELAMINATED. REMOVED RH I/B FLAP T/E WEDGE PER SRM 51-40-02. LOCATED AND DRILLED NEW WEDGE ASSY P/N: 113A2550-604 PER SRM 51-40-05.;[04] APPLIED SURFACE FINISH PER AMM 51-21-99;[05] INSPECTION VERIFIED CORRECTIVE ACTION STEPS 1 THRU 4. OK TO INSTALL WEDGE ASSEMBLY.;[06] INSTALLED NEW WEDGE ASSY P/N: 113A2550-604 PER SRM 51-40-02.;[07] INSPECTION VERIFIED CORRECTIVE ACTION STEP 6.;[08] INSTALLED PANEL 653ET REFERENCE SOPM 20-50-01.;[09] C/W OF INSPECTION STEP 8 ABOVE.;[10] C/W