What was found
CRACK STIFFENER FLOOR STRUCTURE PLATE LOCATED AT BS 540 BETWEEN LBL 24.5 AND LBL 45 WL 208.1 CENTER SECTION 2022-688200<[01] REPLACED STIFFENER FLOOR STRUCTURE PLATE LOCATED AT BS 540 BETWEEN LBL 24.5 AND LBL 45 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-10-02; ITEM 9; SRM 51-40-02 AND DWG NO. 143A0060; SHEET 2; REV. B<BR>SEE INDIVIDUAL SING OFFS BELOW.;[02] TASK CARD COMPLETED RII CERTIFIED;[03] CORRECTED STEP 1. <BR>REPLACED STIFFENER FLOOR STRUCTURE PLATE LOCATED AT BS 540 BETWEEN LBL 24.5 AND LBL 45 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-10-02; ITEM 9; SRM 51-40-02 AND DWG NO. 143A0060; SHEET 2; REV. B <BR>SEE INDIVIDUAL SIGN OFFS BELOW.;[04] TASK CARD COMPLETED RII CERTIFIED