What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 LBL0 WL 208.1 CENTER SECTION 2022-688143<[01] TOOL USED: DIGITAL CALIPER P/N: 500-196-30; S/N:A21033538; DUE DATE: 25-SEP-23.;[02] REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING 273A9110; SHEET 3; REV - DRAWING 273A9112-45;[03] CORRECTED STEP 2. REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING 273A9110; SHEET 3; REV - DRAWING 273A9112 SHEET 30 REV. -;[04] CORRECTED STEP 2. REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 BL0 WL 208.1 CENTER SECTION IAW B737-700 SRM 51-40-02 AND DRAWING 273A9110; SHEET 3; REV - DRAWING 273A9112 SHEET 30 REV. -