What was found
MAIN CABIN AFT WET AREA BETWEEN BS 1016 AND AFT PRESSURE BULKHEAD RBL 3, FLOOR SUPPORT STRAP UPPER SURFACE CORRODED. REMOVED AND REPLACED FLOOR SUPPORT STRAP IAW SRM 51-40-02-0G-0, AND DWG 147A5730.