What was found
CRACK FOUND ON RT HORIZONTAL STAB LOWER SURFACE SS-193.90 17' FROM THE REAR SPAR. CRACK LENGTH 1.0625'. REMOVED CRACK IAW 55-10-01-2R-2 REPAIR 2. PERFORMED LAYOUT AND FABRICATED NEW FILLER AND LOCATED AND DRILLED FIRST SIZE ON REPAIR IAW SRM 55-10-01-2R-11, REPAIR 11 JOB. FABRICATED A NEW DOUBLER. LOCATED & DRILLED IAW SRM 55-10-01-2R-11, REPAIR 11. TREATED & PRIMED DOUBLER, FILLER & AREA IAW AMM 51-21-41-370-803 & AMM 51-21-72-370-803. INSTALLED THE DOUBLER & FILLER IAW SRM 55-10-01-2R-11.