What was found
IN THE FWD CARGO COMPARTMENT; THE RIGHT HAND SIDE PLATE FROM STATION 500B TO 500C HAS AREAS OF UPPER SURFACE CORROSION.<[01] REMOVED DAMAGE PER SRM 51-10-02 AND FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2.;[02] DRILLED NEW TRANSITION ANGLE FOR RIGHT AFT IN FWD LOWER CARGO PER SAMPLE AND SRM 51-40-05 AND COUNTER SINK PER SRM 51-40-08.;[03] REPLACEMENT OF RIGHT TRANSITION ANGLE IS FROM STA 500A TO 500I.;[04] OK TO INSTALL FWD LOWER CARGO RIGHT AFT TRANSITION ANGLE FROM 500A TO 500I.;[05] CW INSP.;[06] CW OK TO INSTALL.;[07] REMOVED AND REPLACED WITH NEW PART PER SRM 51-40-02 FROM STA. 500A THRU 500I R/H