What was found
R/H PRESSURE DECK SHEAR TIE AT STA 665 TO 669 RBL 65 TO RBL 70 WL 202 HAS AREA OF CORROSION. REMOVED CORROSION IAW SRM 51-10-02-0G-0; EVALUATED MATERIAL LOSS - ORIGINAL THICKNESS .063'; LOSS OF .006'; REMAINING .057'. NO ALLOWABLE MATERIAL LOSS LIMITS. RECEIVED -8 SHEAR TIE ON BACKSHOP W/O# 44141-0000-0001. TRIMMED; LOCATED AND DRILLED SHEAR TIE IAW SRM 51-40-05-0G-0. TREATED AND PRIMED SHEAR TIE IAW AMM 51-21-41-370-801, AND 51-21-72-370-804.