What was found
AFT CARGO BAY L/H FLOOR TO SIDEWALL SUPPORT PLATE HAS MULTIPLE AREAS OF CORROSION BS 727 TO 847, LBL 22, WL 156. EVALUATED CORROSION AT ALL LOCATIONS AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. FABRICATED A NEW FLOOR TO SIDEWALL SUPPORT PLATE IAW SRM 53-00-53-2R-5 STEP 4.D, DWG 146A7500 AND EA M-22-153-01550, AND EA M 22-153-01550. APPLIED PRIMER IAW SRM 53-00-53-2R-5 STEP 4.J, AND EA M 22-153-01550. THE DAMAGE WAS REPAIRED IAW SRM 53-00-53-2R-5, REPAIR 5, AND EA M-22-153-01550.