What was found
AFT CARGO BAY RIGHT FLOOR TO SIDEWALL SUPPORT PLATE HAD MULTIPLE AREAS OF CORROSION BS 727 - 767, RBL 22, WL 156. EVALUATED CORROSION AT ALL LOCATIONS AND FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. LOCATED AND DRILLED NEW FLOOR TO SIDEWALL SUPPORT IAW SRM 51-40-02-0G-0, SRM 51-40-05-0G-0, AND DWG 146A7500.