What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT RBL 21, BS 747+2, 747+6, 747+9, 747+10, 747+12, 747+14, & 747+18. BLENDED CORROSION AND FOUND OUT OF LIMITS IAW SRM 53-00-53-1A-2. FABRICATED A REPLACMENT FLOOR TO SIDWALL SUPPORT IAW SRM 51-40-05-0G-0, SRM 51-40-08-0G-0, AND DWG 146A7502. APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802. APPLIED PRIMER IAW AMM 51-21-72-370-804.