What was found
CORRODED INTERCOSTAL, BS 294.5 - 312, LBL 11, WL 208. REMOVED DAMAGED INTERCOSTAL IAW SRM 51-40-02. LOCATED AND DRILLED A NEW INTERCOSTAL IAW SRM 51-40-05, AND DRAWING 141A5690. 100% OF ALL PERMANENT OR TEMPORARY FASTENERS HAVE BEEN INSTALLED WITH FAYING SURFACE SEALED. INSTALLED THE NEW INTERCOSTAL IAW SRM 51-40-02-0G-0, AND DWG 141A5690. CORROSION WAS OUT OF LIMITS IAW SRM 53-00-04-1A-1.