What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 FWD SIDE WL208.1 CENTER SECTION. REPLACED ANGLE AND FASTENERS ANGLE FLOOR STRUCTURE LOCATED AT BS 695 BL0 FWD SIDE WL208.1 CENTER SECTION IAW SRM 51-40-02, SRM 51-10-02, AND DWG 237A9110, SHEET 6, REV A.