What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED AT BS 695 RBL24.7 LOWER SURFACE WL 208.1 CENTER SECTION 2022-700744<[01] TOOLS USED: TEMPERATURE CONTROLLER P/N: P3015GOES00000; S/N: 112031023; DUE DATE: 01-FEB-23; CONTROLLER P/N: 48VFL11; S/N: 31448; DUE DATE: 14-JUN-23.;[02] REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 RBL24.7 LOWER SURFACE WL 208.1 CENTER SECTION IAW BOEING 737-700 SRM 51-40-02 AND DWG IAW BOEING 737-700 DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIGN OFF BELOW.;[03] TASK CARD COMPLETED <BR>REPLACED ANGLE AND FASTENERS ON FLOOR STRUCTURE LOCATED AT BS 695 RBL24.7 LOWER SURFACE WL 208.1 CENTER SECTION IAW BOEING 737-700 SRM 51-40-02 AND DWG IAW BOEING 737-700 DWG 273A9110 SHEET 6 REV A. SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII