What was found
CORROSION ON L/H FLOOR TO SIDEWALL SUPPORT, BS500A+4, +10, 500B+2, +6, +10, +14, 500C+1, +14, +18, LBL 25, WL 156. FOUND TO BE OUT OF LIMITS IAW SRM 53-00-53-1A-2. FABRICATED, LOCATED, & DRILLED A NEW FLOOR TO SIDEWALL SUPPORT AND SPLICE IAW SRM 51-40-05-0G-0, DWG 143A7501, REV A, SRM 53-00-53-2R-6. APPLIED CHEMICAL CONVERSION IAW AMM 51-21-41-370-802. APPLIED PRIMER IAW AMM 51-21-72-370-804. INSTALLED SPLICE IAW SRM 53-00-53-2R-6 & NUT PLATES IAW SRM 51-40-10-2R-0.