What was found
AFT CARGO L/H TRANSITION ANGLE HAS MULTIPLE AREAS OR CORROSION BETWEEN STA. 727I - 7727F<[01] REMOVED DAMAGE; ORIGINAL THICKNESS .045IN; REMOVED .007IN; REMAINING THICKNESS .038IN. FOUND TO BE OUT OF LIMITS AS PER AMM 52-00-53-1A-2.;[02] INCORRECT REFERENCE GIVEN.<BR>REMOVED DAMAGE; ORIGINAL THICKNESS .045IN; REMOVED .007IN; REMAINING THICKNESS .038IN. FOUND TO BE OUT OF LIMITS AS PER AMM 53-00-53-1A-2.;[03] INCORRECT REFERENCE GIVEN.<BR>REMOVED DAMAGE; ORIGINAL THICKNESS .045IN; REMOVED .007IN; REMAINING THICKNESS .038IN. FOUND TO BE OUT OF LIMITS AS PER SRM 53-00-53-1A-2.;[04] REMOVED TRANSITON ANGLE AND INSTALLED NEW SECTION OF TRANSITION ANGLE PER SRM SRM 53-00-53-2R-5.;[05] C/W INSPECTION. SEE TSR 202300134 FOR AUTHORIZATION.