What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS312+9 LBL45.<[01] REMOVED CRACKED INTERCOSTAL AT FWD WET AREA BS 312- BS 328 LBL 45 IAW SRM 51-40-02;[02] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 LBL45 IAW SRM 561-40-05 AND DWG# 141A5410 ; OK TO INSTALL;[03] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 LBL45 IAW SRM 51-40-05 AND DWG# 141A5410 ; OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION 3.;[05] INSTALLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 LBL45 IAW SRM 51-40-02 AND DWG# 141A5410;[06] VERIFIED CORRECTIVE ACTION 5 AND MEASUREMENT TABLE