CRACKED FWD ENTRY DOOR MOP SILL BS294+8 LBL55.<[01] VERIFIED APPLICABILITY PER SRM 53-10-15-1A-1<BR><BR>EVALUATED CRACK ON MOP SILL CHORD L=0.90'; WAS FOUND OUT LIMIT AS PER SRM 53-10-15-1A-1.<BR><BR>REMOVED MOP SILL AS PER SRM 51-40-02.;[02] LOCATED AND DRILLED NEW MOP SILL (CHORD); PER SRM 51-40-05 AND DWG 141A8110. OK TO INSTALL;[03] VERIFIED LOCATE AND DRILL; OK TO INSTALL GIVEN;[04] INSTALLED NEW MOP SILL BS 270 TO 360 LBL 55 WL 208.1 IAW SRM 51-40-02-0G-0 DWG 141A8110 REV: A;[05] VERIFIED CORRECTIVE ACTION 4 AND VERIFIED MEASUREMENT TABLE;[06] JOB COMPLETE