What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS312+5 RBL31.<[01] LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 RBL31 IAW SRM 561-40-05 AND DWG# 141A5410 ; OK TO INSTALL;[02] REMOVED CRACKED INTERCOSTAL AT FWD WET AREA BS312 - 328 RBL31 IAW SRM 51-40-02 . LOCATED AND DRILLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 RBL31 IAW SRM 51-40-05 AND DWG# 141A5410 ; OK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION 2.;[04] INSTALLED NEW INTERCOSTAL AT FWD WET AREA BS312 - 328 RBL31 IAW SRM 51-40-02 AND DWG# 141A5410;[05] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE