What was found
CORROSION ON PASSENGER CABIN AFT WET AREA STRAP AT LBL 3 BS 1016+3-1016+13.<[01] CORROSION ON CABIN AFT WET AREA STRAP AT LBL 3 BS 1016+3 IS OUT OF LIMITS; NO FOUND LIMITS ON SRM FOR THIS PART; PART REPAIR BY REMPLACEMENT PER SRM 51-10-02-0G-0 PARA 9;[02] REMOVED STRAP ON CABIN AFT WET AREA BS 1016+3 LBL 3 PER SRM 51-40-02-0G-0;[03] VERIFIED CORRECTIVE ACTION #1<BR>MEASUREMENT TABLE VERIFIED;[04] FABRICATED STRAP IAW SRM 51-40-05 AND DWG147A5620-8. APPLIED CHEMICAL COVERSION COATING AND PRIMER STRAP PER AMM 51-21-41-370-802 AND AMM 51-21-72-370-804. INSTALLED STRAP AT PASSENGER CABIN AFT WET AREA LBL 3 BS 1016+3 PER SRM 51-40-02-0G-0 ADN DWG 147A5600.