What was found
CORROSION ON PASSENGER CABIN AFT WET AREA MOP SILL SPLICE ANGLE AT RBL 41 BS 1006+1. CORROSION ON MOP SILL SPLICE ANGLE IS OUT OF LIMITS; NO FOUND LIMITS ON SRM FOR THIS PART; PART REPAIRE BY REMPLACEMENT PER SRM 51-10-02-0G-0 PARA 9;[02] VERIFIED CORRECTIVE ACTION 1 PART OUT OF LIMITS. REMOVED MOP SILL SPLICE ANGLE AFT WET AREA PASSENGER CABIN AT RBL 41 BS 986+10 TO BS 1016 IAW SRM 51-40. LOCATED AND DRILLED NEW MOP SILL SPLICE ANGLE IAW SRM 51-40-05-0G-0 AND DWG 147A8540; OK TO INSTALL. VERIFIED CORRECTIVE ACTION 4. INSTALLED ASD MOPSILL SPLICE ANGLE IAW SRM 51-40-02 AND IAW DWG#147A8501 AND IAW DWG#147A0070.