What was found
CRACKED INTERCOSTAL AT FWD WET AREA BS344+5 RBL32.<[01] EVALUATED INTERCOSTAL AT FWD WET AREA BS344+5'' RBL32 AND FOUND TO BE OUT OF LIMITS IAW SRM 53-10-51-1A-1; L=0.8'' TOOL USED CALIPER ID: ATS1317 S/N: UNK DUE:08/2023; PART REPLACED PER SRM 51-10-02-0G-0 PART 9.A;[02] -REMOVED INTERCOSTAL AT FWD WET AREA BS344-360 RBL32 WL208.10 IAW SRM 51-40-02-0G-0.<BR>-LOCATED AND DRILLED NEW INTERCOSTAL IAW SRM 51-40-05-0G-0 AND DWG:141A5400.<BR>-OK TO INSTALL.;[03] VERIFIED CORRECTIVE ACTION 1; 2 WITH OK TO INSTALL GIVEN AND MEASUREMENT TABLE;[04] INSTALLED INTERCOSTAL AT FWD WET AREA BS344-360 RBL32 WL208.10 IAW SRM 51-40-02-0G-0 AND DWG:141A5400;[05] VERIFIED CORRECTIVE ACTION 4