What was found
CORROSION ON PASSENGER CABIN AFT WET AREA STRAP AT LBL 18 BS 1016+1; BS 1016+3.<[01] CORROSION ON THIS PART IS OUT OF LIMITS NO ALLOWABLE LIMITS ON SRM FOUND; REPAIR BY REMPLACEMENT PART PER SRM 51-10-02-0G-0 PAR 9;[02] VERIFIED REPLACEMENT OF PART;[03] LOCATED AND DRILLED STRAP AT PASSANGER CABIN AFT WET AREA LBL18 BS 1016+1 PER SRM 51-40-05-0G-0 AND DWG 147A5600. OK TO INSTALL STRAP;[04] REMOVED STRAP ON PASSANGER CABIN AFT WET AREA LBL 18 BS 1016 + PER SRM 51-40-02-0G-0;[05] VERIFIED CORRECTIVE ACTION STEPS 3 AND 4.;[06] INSTALLED STRAP AT PASSANGER CABIN AFT WET AREA LBL 18 BS 1016 +1 PER SRM 51-40-02-0G-0 AND DWG 147A5600;[07] VERIFIED CORRECTIVE ACTION 6 AND MEASUREMENT TABLE