What was found
CORROSION ON PASSENGER CABIN AFT WET AREA 1016 FLOOR WEB AT LBL 5 BS 1016+12; LBL 9 BS 1016+1; LBL 12 BS 1016+11. THE PART NO HAVE ALLOWABLE DAMAGE ON SRM FOUND TO BE OUT OF LIMITS. PART REPAIR BY REMPLACEMENT PER SRM 51-10-02 PAR 9. LOCATED AND DRILLED NEW WEB ON PASSENGER CABIN AFT WET AREA BS 1016 LT PER SRM 51-40-05. INSTALLED NEW WEB AT PASSANGER CABIN AFT WET AREA 1016 BETWEEN BL 0 TO LBL 40 PER SRM 51-40-02-0G-0 AND DWG 147A5600.