What was found
CENTER CABIN STA. 540 LBL 1 FLOOR PANEL SUPPORT ANGLE IS CRACKED AT FASTENER HOLE. MRKD<[01] REMOVED AND REPLACED CABIN FLOOR SUPPORT PER SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CENTER CABIN STA. 540 LBL 1 FLOOR PANEL SUPPORT ANGLE IS CRACKED AT FASTENER HOLE. MRKD<[01] REMOVED AND REPLACED CABIN FLOOR SUPPORT PER SRM 51-40-02.