As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
R/H AFT SERVICE DOOR EMERGENCY EXIT LIGHT INOP<[01] REMOVED AND REPLACED 2EA EMERGENCY LIGHT BATTERY PACKS PER AMM 33-51-06. OPERATIONAL CHECK NORMAL OF EMERGENCY LIGHTS PER AMM 33-51-00. REFERENCE CARD TTG8Q00HCN6F FOR PARTS INSTALLED.;[02] INSPECTED