What was found
CORROSION ON INTERCOSTAL ATTACH TAB AT AFT CARGO BAY BS767+1; RBL22.<[01] EVALUATED CORROSION ON INTERCOSTAL ATTACH TAB BS 767+1 RBL 22 WL 156; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 AND THE MEASUREMENT TABLE.;[03] REMOVED AND REINSTALLED INTERCOSTAL ATTACH TAB AT AFT CARGO BAY BS767; RBL22. IAW SRM 51-40-02-0G-0 AND DWG 146A0081.;[04] VERIFIED CORRECTIVE ACTION 3.