What was found
CORROSION ON FWD SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767+6 RBL21.<[01] CORROSION ON ANGLE WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM;[02] VERIFIED CORRECTIVE ACTION 1 AND MEASUREMENT TABLE;[03] REMOVED DAMAGED SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767+6 RBL21 IAW SRM 51-40-02-0G-0.;[04] LOCATED AND DRILLED NEW FWD SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767+6 RBL21 IAW SRM 51-40-05-0G-0 AND 146A8123.<BR>OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4 AND MEASUREMENT TABLE.;[06] INSTALLED SHIELD ATTACH ANGLE AT AFT CARGO BAY BS767 -787 RBL21 EXCEPT FASTENER ATTACH ANGLE BS 767+8' RBL18; WILL BE INSTALLED ON CARD # TTG8Q00GYGYP IAW SRM 51-40-02-0G-0 AND 146A8123.;[07] VERIFIED CORRECTIVE ACTION 6.