What was found
CORROSION ON INTERCOSTAL AT AFT CARGO BAY BS767+9; RBL6.<[01] EVALUATED CORROSION ON INTERCOSTAL BS 767+9 RBL 6 WL 152; FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS IN THE SRM AND REQUIRES REPLACEMENT PER SRM 51-10-02-0G-0;[02] VERIFIED CORRECTIVE ACTION 1 AND TE MEASUREMENT TABLE.;[03] REMOVED INTERCOSTAL AT BS BS767 TO BS 787; RBL6 PER SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW INTERCOSTAL AT BS BS767 TO BS 787; RBL6 PER SRM 51-40-05-0G-0 AND DWG 146A8130. OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION 4.;[06] INSTALLED INTERCOSTAL AT BS BS767 TO BS 787; RBL6 PER SRM 51-40-02-0G-0 AND DWG 146A8130;[07] VERIFIED CORRECTIVE ACTION #6