What was found
CORROSION ON PASSENGER CABIN STRAP AT BS 693 LBL 65. BELOW CREASE BEAM. WL 202.<[01] REMOVED CORROSION ON PASSENGER CABIN STRAP AT BS 693 LBL 65 IN AN AREA OF 0.3X0.5 IAW SRM 51-10-02-0G-0;[02] COMPLETED STEP 1;[03] REMOVED 1EA FASTENER AT B.S 693 LBL 65 IAW SRM 51-40-02-0G-0;[04] STEP 1 COMPLETED.;[05] COMPLETED STEPS 2; 3 AND 4.;[06] MEASUREMENTS FOR THE AREA ARE 0.3X0.5X0.069; AREA FOUND TO BE OUT OF LIMITS; IAW SRM 51-10-02-0G-0 NO SRM ALLOWABLE DAMAGE FOR THE AREA IN;[07] AS PER EA 23-153-00073; THE DAMAGE IS ACCEPTABLE AS A CONTINUE-IN-SERVICE CONDITION WITHOUT REPETITIVE INSPECTIONS AND NO TERMINATING ACTION REQUIREMENTS.;[08] VERIFIED CORRECTIVE ACTION #7 AND MEASUREMENT FIELD