What was found
CORROSION ON PASSENGER CABIN STRAP AT BS 693 RBL 61. BELOW CREASE BEAM. WL 202.<[01] REMOVED CORROSION ON PASSENGER CABIN STRAP AT BS 693 RBL 61 IN AN AREA OF 0.8X1.1 IAW SRM 51-10-02-0G-0;[02] REMOVED 1EA FASTENER AT B.S 693 RBL 61 IAW SRM 51-40-02-0G-0;[03] COMPLETED STEP 1;[04] STEP 1 COMPLETED.;[05] COMPLETED STEPS 2; 3 AND 4.;[06] CORRECTED ITEM #14 ON MEASUREMENTS;[07] AREA FOUND TO BE OUT OF LIMITS; NO ALLOWABLE DAMAGE FOR THE IAW SRM 51-10-02-0G-0;[08] VERIFIED CORRECTIVE ACTIONS STEP 7. VERIFIED MEASURMENTS TABLE.;[09] AS PER EA 23-153-00075; THE PN 144A7713-4 ANGLE WAS REMOVED AND REPLACED. THE DAMAGE TO THE PN 144A7713-2 ANGLE IS ACCEPTABLE AS A CONTINUE-IN-SERVICE CONDITION WITHOUT REPETITIVE INSPECTIONS AND NO TERMINATING ACTION REQUIREMENTS.;[10] VERIFIED MEASUREMENT FIELD;[11] VERIFIED CORRECTIVE ACTION #9