What was found
CORROSION EXTERNAL SKIN VERTICAL FIN AFT EDGE LOCATED APROX. STA 169.0 AT VERTICAL STABILIZER 2022-694959<[01] TOOL USED ULTRASONIC EQUIPMENT PN: 45MG; SN: 130064101; DUE DATE: 12 OCT 23;[02] REMOVED DAMAGE AND REWORKED AREA FOUND WITHIN LIMITS IAW B737-700 SRM 55-30-01-1A-2 AD2 FIG. 104 DETAIL F; WITH EXACTLY LOCATION CORROSION EXTERNAL SKIN VERTICAL FIN AFT EDGE LOCATED APROX. STA 169.0 AT VERTICAL STABILIZER RH SIDE; NOT FURTHER ACTION OR REINSPECTION REQUIRED; SEE INDIVIDUAL SIGN OFF BELOW.;[03] REMOVED DAMAGE AND REWORKED AREA FOUND WITHIN LIMITS IAW B737-700 SRM 55-30-01-1A-2 AD2 FIG. 104 DETAIL F; WITH EXACTLY LOCATION CORROSION EXTERNAL SKIN VERTICAL FIN AFT EDGE LOCATED APROX. STA 169.0 AT VERTICAL STABILIZER RH SIDE; NOT FURTHER ACTION OR REINSPECTION REQUIRED; SEE INDIVIDUAL SIGN OFF BELOW